º» »óÇ°Àº 2024/04/26ÇöÀç ¼­¹ö±×·ì º¸À¯ LIST ÀÔ´Ï´Ù °ü¸®¹øÈ£ : 56259

SUN SUN T1405 NETRA

Á¦Á¶»ç   SUN
¸ðµ¨¸í   SUN NETRA T1405
ÆÄÆ®¹øÈ£   SUN T1405 NETRA
º¸À¯¼ö·®   3 ea
°¡°Ý   3,300,000 ¿ø
ÀÓ´ë°¡°Ý   
º¸Áõ±â°£   6°³¿ù
 

 

Racking Fits into 19-, 23-, 24-in., 600-mm racks (requires mounting kit,19-in.flanges supplied with product, others available as options) Processor Number Up to four Architecture 440-MHz, 64-bit, UltraSPARC II Cache memory 16 KB data and 16 KB instruction on chipSecondary: 4 MB external (per CPU module) Main Memory Capacities Total of 16 DIMM memory slots availableUp to 4 GB (DIMMS must be installed in sets of four) Standard Interfaces Alarm card One alarm port (DB15) with relay connections for for Ethernet, ATM, and serial I/O One RS-232/RS-423 asynchronous LOM port (RJ-45) Ethernet One ethernet/fast ethernet (10BASE-T/100BASE-T) shielded twisted-pair port (RJ-45) Keyboard and mouse One standard keyboard/mouse port (mini DIN-8 ) (this is not an NEBS compliant port) Parallel One Centronics-compatible parallel port (DB25); ECP mode capable PCI Four full-size PCI 2.1 compliant slots: Slot 1: 64-bit, 33- or 66-MHz, 5.0/3.3 V Slots 2 & 3: 32- or 64-bit, 33-MHz, 5.0/3.3 V Slot 4: 32-bit, 33-MHz, 5.0/3.3 V SCSI One 40-MB/sec, 68-pin, UltraSCSI (SCSI-3) port Serial Two RS-232/RS-423 asynchronous/synchronous serial ports (DB25) SCSI 40-MB/sec.Ultra SCSI Internal Mass Storage Disks Up to four 18-or 36-GB disks CD-ROM/DVD-ROM Optional SunCD 32Optional 10X-speed DVD-ROM, equivalent to 40X-speed CD-ROM Tape Optional 12-to 24-GB DDS3, 4 mm Power Supply AC power (Netra t 1405) Three (n +1 redundant) AC power supplies 100/240 V AC nominal,330 W,dual input DC power (Netra t 1400) Three (n +1 redundant) DC power supplies 48/60 V DC nominal,330 W,dual input Environment AC input 90 – 264 VAC, 47 – 63 Hz, 4 A, 0.4 KVA DC input -48 to -60 VDC, 10 A @ -48 VDC, 12 A @ -60 VDC Heat output 2254 BTU/hr Temperature 1 Operating: 5¡Æ C to 40¡Æ C (41¡Æ F to 104¡Æ F) Operating (short term): -5¡Æ C to 55¡Æ C (23¡Æ F to 131¡Æ F) Nonoperating: -40¡Æ C to 70¡Æ C (-40¡Æ F to 158¡Æ F) Humidity Operating: 5% to 85% relative humidity, noncondensing Nonoperating: 10% to 95% relative humidity, noncondensing Altitude Operating: -300 m to 3000 m (-1000 ft. to 10,000 ft.) Nonoperating: -300 m to 12,000 m (-1000 ft. to 40,000 ft.) ETSI ETS 300-19-2-3 Acoustic noise Operating: <60dBA Idling: <60dBA Seismic Meets GR-63-CORE requirements for earthquake risk zone 4 Meets ETS 300-19-2-3, A1 operating requirements Number of cords 3 1 – Short term is defined as no more than 96 hours duration at extremes and at elevations less than 1800m.