Racking
Fits into 19-, 23-, 24-in., 600-mm racks (requires mounting kit,19-in.flanges supplied with product, others available as options)
Processor
Number Up to four
Architecture 440-MHz, 64-bit, UltraSPARC II
Cache memory 16 KB data and 16 KB instruction on chipSecondary: 4 MB external (per CPU module)
Main Memory
Capacities Total of 16 DIMM memory slots availableUp to 4 GB (DIMMS must be installed in sets of four)
Standard Interfaces
Alarm card One alarm port (DB15) with relay connections for for Ethernet, ATM, and serial I/O
One RS-232/RS-423 asynchronous LOM port (RJ-45)
Ethernet One ethernet/fast ethernet (10BASE-T/100BASE-T) shielded twisted-pair port (RJ-45)
Keyboard and mouse One standard keyboard/mouse port (mini DIN-8 ) (this is not an NEBS compliant port)
Parallel One Centronics-compatible parallel port (DB25); ECP mode capable
PCI Four full-size PCI 2.1 compliant slots:
Slot 1: 64-bit, 33- or 66-MHz, 5.0/3.3 V
Slots 2 & 3: 32- or 64-bit, 33-MHz, 5.0/3.3 V
Slot 4: 32-bit, 33-MHz, 5.0/3.3 V
SCSI One 40-MB/sec, 68-pin, UltraSCSI (SCSI-3) port
Serial Two RS-232/RS-423 asynchronous/synchronous serial ports (DB25)
SCSI 40-MB/sec.Ultra SCSI
Internal Mass Storage
Disks Up to four 18-or 36-GB disks
CD-ROM/DVD-ROM Optional SunCD 32Optional 10X-speed DVD-ROM, equivalent to 40X-speed CD-ROM
Tape Optional 12-to 24-GB DDS3, 4 mm
Power Supply
AC power (Netra t 1405) Three (n +1 redundant) AC power supplies
100/240 V AC nominal,330 W,dual input
DC power (Netra t 1400) Three (n +1 redundant) DC power supplies
48/60 V DC nominal,330 W,dual input
Environment
AC input 90 – 264 VAC, 47 – 63 Hz, 4 A, 0.4 KVA
DC input -48 to -60 VDC, 10 A @ -48 VDC, 12 A @ -60 VDC
Heat output 2254 BTU/hr
Temperature 1 Operating: 5¡Æ C to 40¡Æ C (41¡Æ F to 104¡Æ F)
Operating (short term): -5¡Æ C to 55¡Æ C (23¡Æ F to 131¡Æ F)
Nonoperating: -40¡Æ C to 70¡Æ C (-40¡Æ F to 158¡Æ F)
Humidity Operating: 5% to 85% relative humidity, noncondensing
Nonoperating: 10% to 95% relative humidity, noncondensing
Altitude Operating: -300 m to 3000 m (-1000 ft. to 10,000 ft.)
Nonoperating: -300 m to 12,000 m (-1000 ft. to 40,000 ft.)
ETSI ETS 300-19-2-3
Acoustic noise Operating: <60dBA
Idling: <60dBA
Seismic Meets GR-63-CORE requirements for earthquake risk zone 4
Meets ETS 300-19-2-3, A1 operating requirements
Number of cords 3
1 – Short term is defined as no more than 96 hours duration at extremes and at elevations less than 1800m.
|